10.4" TFT LCD screen | High precision flowmeter |
Breathing circuit
|
Displays the Ventilation parame
ters, Alarm information and
Oscillogram.
|
instantly know the fresh gas flow to
your patient.
|
Integrated breathing circuit design,
ensure easy operating and keep tidy
|
Bellow, APL valve
|
Vaporizer | Pressure gauge |
Integrated bellow 0mL-1500mL.
Suitable for all range patients.
Automatic decompression to ensure safety.
|
Accurately delivers a calibrated flflow,
Halothane, Enflflurane, Isoflflurane,
Sevoflflurane for choice. Suitable for
low flflow anesthesia, save cost.
|
Real time pressure. |
Optional Part 1 | Optional Part 2 | |
Vital sign monitor and anesthetic gas monitor. |
ETCO2 module and Anesthesia Gas Scavenging System (AGSS). |
Ventilation mode |
IPPV, V-A/C, P-A/C, V-SIMV, P-SIMV, PCV-PC, PCV-VG, PSV, SIGH, MANUAL
|
Ventilator parameter range | |
Flowmeter |
O2 (0 ~ 10 L/min)
N2O (0 ~ 10 L/min)
or AIR (0 ~ 10 L/min)
|
Rapid oxygen supply | 25 L/min - 75 L/min |
Tidal volume |
0, 20 mL ~ 1500 mL
|
Frequence(Freq) | 1 /min - 100 /min |
I:E | 4:1 - 1:8 |
PEEP | 0 cmH2O - 30 cmH2O |
Pressure triggering sensitivity (PTr) | -20 cmH2O - 0 cmH2O (Based on PEEP) |
Flow trigger sensitivity (FTr) | 0.5 L/min - 30 L/min |
Pressure control (PC)
|
5 cmH2O ~ 70 cmH2O
|
SIGH | 0 (off) 1/100 - 5/100 |
Apnea ventilation | OFF, 5s - 60s |
Pressure limit | 10 cmH2O - 100 cmH2O |
Alarm and protection | |
The AC power failure alarm | Power failure or no connection |
Internal battery backup low voltage alarm |
< 10.2 ± 0.3 V
|
No tidal volume | ≤ 5 mL within 6 s |
High oxygen concentration alarm | 19 % - 100 % |
Low oxygen concentration alarm | 18 % - 99 % |
High airway pressure alarm | 2 cmH2O - 100 cmH2O |
Low airway pressure alarm | 0 cmH2O - 20 cmH2O |
High minute volume alarm |
Adult (5 L/min ~ 20 L/min)
|
Low minute volume alarm |
Paed (1 L/min ~ 15 L/min, 0 ~ 10 L/min)
|
Continuous pressure alarm | (PEEP+1.5 kPa) over 16 s |
Suffocation warning | 5 s - 60 s no spontaneous ventilation |
The maximum limited pressure | ≤ 12.5 kPa |
Fan error | Show on screen |
Oxygen deficit | Show on screen |
Monitoring parameter | |
Frequence(Freq) | 0 /min - 100 /min |
Tidal volume (Vt) | 0 mL - 2000 mL |
MV | 0 L/min - 100 L/min |
Oxygen concentration | 15 % - 100 % |
Working condition | |
Gas source | O2, N2O, AIR |
Pressure | 280 kPa ~ 600 kPa |
Voltage | 100 ~ 240 V |
Power frequency | 50/60 Hz |
Input power
|
80 VA
|
Oscillogram |
P-T (pressure - time) |
F-T (flow - time) |
P-V loop (pressure - volume loop) |
ETCO2-T (ETCO2-time)
|
P-V loop (pressure-volume loop) |
P-F loop (pressure-flflow loop) |
F-V loop (flflow-volume loop) |
Wooden case packing size |
Wooden case packing size : L 920* W 970* H 1380 mm |
G.W. :155 KG N.W. :87.5 KG CBM :1.23 m³ |