Contact Us
The S6500 Anesthesia System performs exceptionally well in various healthcare settings, including ICUs, Operation Rooms, and Anesthesiology Departments. It is designed for adult, pediatric, and neonatal inhalation anesthesia and respiratory management, offering advanced ventilation modes.
With its professional and ergonomic design, the system ensures optimal safety, stability, and convenience for users. It prioritizes user experience while maintaining a high level of safety.
The latest model, S6600 Anesthesia System, incorporates cutting-edge technology, providing enhanced comfort for doctors and improved patient safety. It represents the pinnacle of anesthesia machine development, offering a superior experience for both medical professionals and patients.
Trust point
Application
The S6600 Anesthesia System is specifically designed to meet the anesthesia needs of both adult and pediatric patients. It offers advanced features and functions that make it suitable for a wide range of applications in various medical environments.
In adult anesthesia, the S6600 system precisely controls and monitors anesthesia delivery, ensuring optimal safety and effectiveness during procedures. It offers a range of ventilation modes and advanced monitoring features to support accurate and tailored anesthesia management for adult patients.
When it comes to pediatric anesthesia, the S6600 system excels at delivering expert care to young patients. It contains dedicated features and settings to meet the unique physiology and requirements of pediatric anesthesia. This includes precise control of anesthesia depth, dedicated ventilation modes, and monitoring features tailored for pediatric patients.
Mechanical flowmeter Emergency situation and spare-use for doctor. Built-in electronic flowmeter "High precision flowmeter, instantly know the fresh gas flow to your patient. O2 and N2O linkage device ensure O2 concentration no less than 25%." |
|
Breathing circuit and bellow Integration breathing circuit and bellow design, ensure easy operating and keep tidy. With bypass and heating function. APL valve Decompression automatic to ensure safety Oxygen concentration detector Real-time monitoring of oxygen concentration for safety ACGO and fast oxygen supply Emergency situation and revival after operation. CO2 absorber 1.2L With bypass function and heating function, can be directly disassembled and replaced the Soda Lime during operation. Make sure the comfort level of patients and also avoid backflow of condensate water. |
15” TFT LCD touch screen
|
Other optional parts
|
6 auxiliary plugs
|
Extra-large screen, high sensitivity touch give you better operating experience.
Displays the ventilation parameters, alarm information and oscillogram.
|
Anesthetic gas monitor, vital
signs monitor: real-time
monitoring of anesthetic gas
and patient′s condition.
|
VGA RS232 USB connector
and ETCO2
AGSS (optional part)
|
Auxiliary O2 supply
|
Vaporizer |
O2 and air supply
|
Provide fresh oxygen to the
patient for independent use.
|
Accurately delivers a calibrated flow, Halothane, Enflurane, Isoflurane, Sevoflurane for choice. Suitable for low flow
anesthesia, save cost.
|
Provide fresh oxygen or air to the patient for independent use.
|
Ventilation mode |
V-CMV, V-SIMV, P-CMV, P-SIMV, PSV, PCV-VG, MANUAL
|
Ventilator parameter range
|
|
Tidal volume(Vt) | 0, 10 mL ~ 1500 mL |
Frequence(Freq) | 4 /min ~ 100 /min |
I:E | 4:1 ~ 1:10 |
PEEP | 0 cmH2O ~ 30 cmH2O |
Rapid oxygen supply | 25 L/min ~ 75 L/min |
Pressure trigger | 0 kPa ~ 30 cmH2O |
Flow trigger | 0.3 L/min ~ 15 L/min |
Pressure support | 3 cmH2O ~ 50 cmH2O |
Pressure limit | 10 cmH2O ~ 100 cmH2O |
Inspiration apnea | OFF, 5 % ~ 60 % |
Inspiration time | 0.2 s ~ 5 s |
Trigger | 5 % ~ 95 % |
SIMV frequency | 4 /min ~ 60 /min |
Rise time | 0 s ~ 2 s |
Flowmeter | O2 (0 ~ 15 L/min) |
N2O (0 ~ 15 L/min) | |
AIR (0 ~ 15 L/min) |
Alarm and protection | |
VT upper limit | 5 mL ~ 2000 mL |
VT lower limit | 0 mL ~ 1995 mL |
MV upper limit | 0.1 L/min ~ 100 L/min |
MV lower limit | 0.0 L/min ~ 99.9 L/min |
Respiration frequency upper limit | 2 /min ~ 100 /min |
Respiration frequency lower limit | 0 /min ~ 98 /min |
FIO2 upper limit | 20 % ~ 100 % |
FIO2 lower limit | 18 % ~ 98 % |
Airway pressure upper limit | 2 cmH2O ~ 100 cmH2O |
Airway pressure lower limit | 0 cmH2O ~ 98 cmH2O |
Apnea | 20s, 25s, 30s, 35s, 40s, 45s, 50s, 55s, |
Oxygen concentration never lower than 25 % when N2O start |
Monitoring parameter | |
Frequence (Freq) | 0 /min ~ 100 /min |
Tidal volume (Vt) | 0 mL ~ 2500 mL |
Minute volume | 0.1 L/min ~ 99.9 L/min |
Oxygen concentration | 15 % ~ 100 % |
Airway pressure | -20 cmH2O ~ 100 cmH2O |
Inspiration platform pressure | 0 cmH2O ~ 100 cmH2O |
PEEP | 0 cmH2O ~ 70 cmH2O |
I:E | 4:1 ~ 1:10 |
Oscillogram | Testing |
P-T (pressure-time) | Automatic leakage compensation testing |
F-T (flow-time) | Patient circuit leakage compensation and automatic compliance compensation |
V-T (volume-time) | Patient monitor and AG monitor can be equipped |
ETCO2 -T (ETCO2 -time) | Manual ventilation, mechanical ventilation and standby |
P-V loop (pressure-volume loop) | Oscillogram: P-T, F-T, V-T, Lung function loop, ETCO2 |
F-V loop (flow-volume loop) | Self-testing visible |
F-P loop (flow-pressure loop) | Alarm visible |
ACGO function |
Wooden case packing size :L 1005 * W 960 * H 1700 mm |
G.W. :253 KG N.W. :132 KG CBM : 1.650 m3 |
Send your inquiry directly to us