Place of Origin:
China
Brand Name:
Better
Certification:
iso, Cfda
Model Number:
VE06E
Contact Us
Precision Coblation Plasma Surgery System for Tonsillectomy,Adenoidectomy Operations
Product Introduction
It is design specially for Tonsillectomy, Adenoidectomy, CAUP, UPPP, and nasal cavity lesion tissue treatment. Tonsillary and adenoidectomy, UPPP, CAUP, and nasal cavity lesion treatment. The diameter is thinner, which is more convenient for children to use; the liquid enters and exits in two channels and is separated separately, which can effectively prevent the cutter head from being blocked, and the electrode surface of the cutter head is plated with special metal for longer use. It has the function of cutting, ablation, hemostasis and coagulation. It is connect with SPK100 ENT plasma surgery system to perform the operation.
Product Tip Picture
Product Application
Product Advanatages
System Set Up
Description | Remark |
Manufacturer Logo | BETTER Brand. |
Working Frequency | 50Hz |
Receptacle of Footswitch | Connects with Footswitch which determines ablation or coagulation mode. |
Receptacle of Treatment Handle | Connects with the treatment accessories. |
Power Switch | System start power button. “O” means power off; “I” means power on. |
ABLATION mode Selector | Select ABLATION mode 1 or 2 Output waveform. |
Indicator of Treatment Probe Connection | LED turns on green when the probe cable is connected and turns on red when it is not connected. |
Indicator of Footswitch Connection | LED turns on green when the footswitch cable is connected and turns on Red when it is not connected. |
ABLATION Power Setting Display |
Shows the preset ABLATION output value in two digits. “01” with Min. power output, and “10” with the highest output. |
Ablation Output Power Up/Down Button | The number displayed indicates the ablation nominal power, in watts, which will be delivered to the patient when the mode is activated. Only available for changing in ready mode. |
Anesthesia
General anesthesia
Cutting Principle
Relying on the mechanical kinetic energy of the plasma in the electric field, it hits the molecular bonds (40-70 ° C) of the target tissue to lyse and ablate. The thermal damage depth is less than 0.5mm, and the trauma to normal adjacent tissues is small.
Treatment Diseases
Tonsillectomy, Adenoidectomy, CAUP, UPPP and the soft tissue at narrow spaces like nasal cavity.
Storage Condition
Electrodes shall be stored in environment of humidity less than 80%. no corrosive gas, well vented room. Taking complete protection to electrodes.