The DM6A veterinary anesthesia system is highly regarded and extensively utilized in veterinary clinics, hospitals, and research laboratories worldwide, receiving consistent acclaim from customers. Its specialized design enables safe, user-friendly, and precise inhalation anesthesia administration. With minimal resistance to respiration, the system offers rapid control over anesthesia depth, catering to a wide spectrum of acuity levels, from simple to complex cases, and accommodating animals of various sizes, such as dogs, cats, rabbits, mice, birds, and more. Renowned for its reliability and versatility, the DM6A veterinary anesthesia system plays a crucial role in ensuring optimal anesthesia management for a diverse range of veterinary procedures.
Safety
Ventilation mode | |
IPPV,A/C,PCV,SIMV,SIGH,MANUAL | |
Ventilator parameter range | |
Flowmeter | O2 (0~5L/min) |
Rapid Oxygen Supply | 25L/min~75L/min |
Tidal Volume (Vt) | 0, 20 mL ~ 1500 mL |
Frequency (Freq) | 1/min~100/min |
I:E Ratio | 2:1~1:6 |
Pressure Triggering Sensitivity | -20 cmH2O~0 cmH2O (Based on PEEP) |
Flow Trigger Sensitivity | 0.5 L/min ~ 30 L/min |
SIGH | 0 (off) 1/100 ~ 5/100 |
Apnea Ventilation | OFF,5 s ~ 60 s |
Pressure Limit | 20 cmH2O ~ 100 cmH2O |
Monitoring parameter | |
Frequency (Freq) | 0/min ~ 100/min |
Tidal Volume (Vt) | 0 mL ~ 2000 mL |
Minute Volume (MV) | 0 L/min ~ 100 L/min |
Oxygen concentration | 15 % ~ 100 % |
Alarm and protection | |
The AC power failure alarm | Power failure or no connection |
Low voltage alarm for back up battery | <11.3±0.3V |
No tidal volume | ≤5mL within 6s |
High oxygen concentration alarm | 19%-100% |
Low oxygen concentration alarm | 18%-99% |
High airway pressure alarm | 20cmH2O-100cmH2 |
Low airway pressure alarm | 0cmH2O-20cmH2O |
High minute volume alarm | 1L/min-20L/min |
Low minute volume alarm | 0L/min-10L/min |
Continuous pressure alarm | (PEEP+1.5kPa) over 16s |
Suffocation warning | 5s-60s no spontaneous ventilation |
The maximum limited pressure | <12.5 kPa |
Fan error | Show on screen |
Oxygen deficit | Show on screen |
Working condition | |
Gas Source | O2, N2O |
Pressure | 280kPa-600kPa |
Voltage | 100-240V |
Power Frequency | 50/60Hz |
Oscillogram | |
P-T (pressure – time) | |
F-T (flow – time) | |
P-V loop (pressure – volume loop) | |
V-T (volume – time ) | |
ETCO2-T (ETCO2 – time) |
Size | |
Wooden case packing size | L 740*W 795*H 1540mm |
G.W. | 119KG |
N.W. | 66KG |
CBM | 0.99m3 |